Skip to main content

Local 940X90

Unable to get working directory ansys


  1. Unable to get working directory ansys. AnalysisNames [0]) anWD=an1. August 14 May 14, 2024 · Before "fdtd. I created its geometry in the design modeller and then moved onto the model section. old Unable to view geometry. 求助,软件报错“un. You can go to Options -> Mechanical -> Analysis Settings and Solution and specify a location, See if changing the location helps or not. 2 installed on Windows 10 OS. Jul 16, 2013 · If you suspect that somehow your project database for a Mechanical model (or any other model that uses the same interface as ANSYS Mechanical) has been corrupted, you just might be able to recover it using these steps: 1. RT,楼主第一次用ansys,在应力仿真的时候出现了上面的报错,请问各位大佬这个应该怎么解决? 求助,软件报错“unable to get working directory”【ansys吧】_百度贴吧 When you visit any web site, it may store or retrieve information on your browser, mostly in the form of cookies. Click the down-arrow icon ( ) next to the directory name. DataModel. Analysis object remains linked to the wrong "file. I can not find any relevant solutions anywhere, and was wondering if anyone here has a solution. Locate the Ansys folder and rename it to Ansys. Has anyone any ideas on how I can get around this? I appreciate the help. Jun 19, 2022 · Thank you for your help, I solved this problem by changing the directory in Fluent Launcher. It's free to sign up and bid on jobs. Oct 23, 2020 · Hello there, nI am not able to open any . Unable to get model (ansys. I've checked the Discovery installation directory, and the nvcuda. Regards, Sampat The folders I was using to run Ansys in were being continually backed up to Google Drive. run() ". Also, as an interim workaround to salvage results already […] 最近这段时间来被ansys虐的不成样子,使用中总是出现各种奇怪的问题,做了近四个通宵解决了部分问题。下面对前段时间出现的问题及解决方法进行总结,日后出现问题也会记录在此,希望能给遇到同样问题的同学一些参… I am running Ansys Discovery AIM on a sever based license (Formula student, 5 sponsored licenses distributed by tunnelling into central computer). Alternatively, you can manually edit your Windows host file‍ as a work around. Other modules of ansys works fine but fluent and cfd doesn't seems to work in parallel. Jan 25, 2023 · Answer: Please try saving the project to a folder path with only characters in current locale. I meshed it, applied loads and […] Feb 5, 2004 · At the end of the run by default it moves everything to be kept out of this directory into the final data directory (C:\CFX\work\axissymmetry\water\ModelAir4000_004 in your case) and deletes the temporary ModelAir4000_004. Note: During solution the solver directory will change to a temporary directory. straight-forward, but doesn't seem to work: anWD=ExtAPI. cmd you can test by adding a line like below beffore the line for silent setup (assuming c:\temp exists) Sep 6, 2022 · It's not working perfectly for me, but this may be an acceptable work around for others experiencing this problem. , to be a default folder for all time| Set Default Folder#Changingworkingdirectory#SetDefa Mar 21, 2022 · I was performing a static structural beam deflection simulation in ANSYS 2022 R1 (Student version). This is specific to the user that is logged into the machine. Nov 16, 2021 · I am using Ansys Fluent Solution 2021 R1, and I would like to change directory in the console to a folder that has a white space in its name, such as "a folder". Model. Manually enter one when starting the server or set it as the environment variable "ANSYS_PATH" and a Mechanical APDL that is not responding. Jul 7, 2023 · By default, scratch folder is blank. Â If your May 12, 2022 · While I was using the Workbench, I found a problem that has never occurred before: "Unable to view geometry, Unable to get model". exe” -g -p ansys -np 2 -lch -dir “C:temp” -j test -s read -l en-us -t -d win32 Note: This example starts 19. This is not uncommon however this time I failed to restart […] Apr 3, 2019 · I've installed Ansys Discovery Live 2019 R1, and it keeps showing this message when I open it and switches to SpaceClaim when I press OK. Since then I haven't changed anything concerning ANSYS directory files or installation parameteres. exe found in the Ansys installation folder. com FREE STUDENT SOFTWARE Login Drag a new Fluent analysis system out of the Toolbox and drop it on the Geometry Cell of the Fluent system that is broken. Client machines connected to the same local network can request and check out the license on the server. mechdat extension. Guidelines for Posting on Ansys Learning Forum Reinstall Ansys Client Software‍ if necessary. exe. This problem occurs in "Steady Structural" but the "Steady-State Thermal" can run normally. Unable to get model. Can anyone please help me out?. Please make sure that config/admin. any idea how to solve that? P Aug 27, 2020 · I renamed the% appdata% / ansys directory to ansys_old I have already done this: Start -> All Programs -> Ansys -> Utilities -> Right Click on Product and Cad Configuration -> Run As administrator I already updated the driver of my video card. Thanks in advance! Jun 22, 2023 · We are working to complete our maintenance by June 28th. A browser window will open. Whenever Ansys shutdowns abnormally it creates a *. Thanks again Ali for your help Apr 28, 2022 · I get "Unable to automatically locate the Ansys path for version 221. old. Though I know there is a possibility of submitting analysis via Workbench (Workbench LS-DYNA), I want to only export keyword file (. Do not leave your license server specified via IP address as not all Ansys features will work properly. ; Via Uninstall. Copy any . So to do that in Workbench I activate Beta options […] Jan 2, 2022 · The folder 'dp0' is the top level design point directory - if you run a parameter study in Workbench you will get many 'dp' folders created, but usually everything happens inside dp0. Ansys Innovation Space Search AIS Search Forum Search Courses Search Certifications Search Knowledge Search Marketplace Search Ansys. AnalysisByName (ExtAPI. Nov 28, 2018 · But don't worry, there's a workaround! Here's how you can access the Ansys Online Help from within the Ansys Student products: Open Ansys Workbench (or any other Ansys product) and go to Help > Ansys Workbench Help. I have linked the solution of the Maxwell simulation to the setup of the mechanical simulation. Jun 30, 2022 · Hello @vinothirudayanathan, As @mikerife suggested, this might be related to installation issue. 2) If that doesn't work can you simply delete the *. (Unable to open file. . workbench显. Click Browse to browse to the directory that you want. aedt file on my computer. No request for license checkout can be seen on the Ansys license manager log files. g. Apr 19, 2024 · I set working dir, num processors and press start. 2. The problem seemed to be that ANSYS was installed in C:\Users\username instead of Program Files. This will transfer the geometry to the new system. During this time, all AIS sites will be available in read-only mode with no login function available. com/account/secured?returnurl=/Views/Secured/corp/v221/en/act_script/act_script_examples_solve_track_core. I tried to ask for help from this email, and got the reply that post on ANSYS forum or submit a service request on the Ansys customer portal, but since I'm using school's system to run LS-OPT, I did not have the license info so I cannot do the second way. For more information, see Stopping the Ansys License Manager . Answer: As a workaround, you can try using a command line like the example below to start Mechanical APDL “C:Program FilesANSYS Incv192ansysbinwinx64ANSYS192. Apr 6, 2023 · You should see a directory named: Ansys, rename that directory to: Ansys. I have ANSYS EDT version 2018. k file), then do some sort of adjustment, and then run it via Mechanical APDL Product Launcher. core. Jun 21, 2023 · The topic ‘Unable to get working directory’ is closed to new replies. The last time I edited my design was on 13/07/2019. For clearing the Temp data-Go to the Start Menu and open %temp% folder. Overview. Project. Unable to remove external enhanced model object in Mechanical. Mar 30, 2023 · Hi, Please check the working directory path and also the memory space available for the Fluent calculations. Feb 19, 2018 · "Update failed for the Setup component in Transient Thermal. Go back and change license specified to the hostname. But It is still unable to be opened and shows the error: "Unable to detect installed products. The solution involves using the ANSYS Product Launcher to specify the directory and the file name. Unable to get model. Each user that runs the simulation on the same machine will have their own client licensing logs. The analysis goes on for a while and then abruptly stops. For demo purposes let's get the working directory for the first analysis: first_analysis = ExtAPI. Open a file explorer and type %appdata% in the address bar. WorkingDir. chdir a folder chdir "a folder" chdir a\ folder chdir a/ folder chdir "a/ folder" chdir "a\ folder" You should use the Stop the Ansys, Inc. Work-around via name: an1=ExtAPI. Â You can determine whether this is the case or not by using “df -h” to see if your home directory is a local disk or NFS server. Oct 1, 2012 · [ORD03143:08783] Error: Unable to get the current working directory where ORD03143 is my computer's name and 08783 is the pid But the program does not stop, it keeps Jul 2, 2015 · I want to run a cfd analysis in Ansys Workbench V16. running always one Design in a study starting from a reference project. Please try setting "Use Distributed Computing (DMP)" instead of "Use Shared-Memory Parallel (SMP)" in MAPDL Product Launcher --> High Performance Computing Set up (as shown below) and try launching MAPDL again by clicking on "Run" button in Product launcher. I've tried updating drivers for both cards. Work-around via children/parents: I'm trying to run a simulation in ANSYS Mechanical, but everytime I attempt to solve the simulation, I get the "Unable to get working directory" Error. 2 using the Mechanical Enterprise license and 2 cores and uses C:temp as the working directory. rst" file due to a loss in deletion-add operations (least for my case). I am getting an error "Unable to get working directory" What is the best way to get the WorkingDir? In documentation I found: 1. Unable to get the locale encoding Ansys does not support the usage of unauthorized Ansys software. Apr 10, 2014 · When installing the software it ask you to associate cad reader or plugin for various CAD software and one more thing you do not need to install the specific software for the reader or plugin to work. This is the 1st time I met this problem, the screenshot is sent as an attachment for your reference. 3. Failure? Continue troubleshooting. The tunnelling software is PuTTY, however during a CFD simulation my internet dropped out and my connection to the licensing computer failed. lock file. It is likely that Ansys and Google were looking at the same files at the same time, and this caused Ansys to crash. We do not recommend stopping the license manager manually; however, if you choose to do so, you must stop the components in the following order: can't create directory "unable to get value "AppData" from key "HKEY_CURRENT_USER": no such file or directory The software works fine under an administrative account on the same machine so it seems to be a permissions related issue. mapdl. Then directly run it on your local computer, and then move to the cluster and run it. I changed the Ansys Workbench temporary directory: But it has no effect on the Fluent job. Rename them to a . html), I get an error reading "Unable to get working directory". An alternative method to uninstall Ansys software is to run the uninstall. ansys. I installed the Ansys Electronics Desktop Student 2023 R2 following the steps and ran the app as administrator. If possible entirely English and simple path such as C:temp and use a short name for Workbench project such as myproject. Feb 3, 2010 · A user asks how to change the default working directory in ANSYS and gets some advice from other users. old’ then launch the application. wbpj Solve again and see if the issue is resolved. Sep 22, 2018 · Hi tomcojocar, Just for a kick, what if you launch Workbench with 'run as administrator' ? When you launch empty Workbench, do you see any Analysis Systems in the Toolbox ? Nov 27, 2023 · 1. May 28, 2022 · Assuming you're talking about ANSYS APDL ("clasic"). Jun 29, 2022 · in my script (this command can be found in the official scripting help under https://ansyshelp. This means you will not be able to create any new forum posts on the Ansys Learning Forum, but you can still browse existing ones. How it was solved. The local computer running Lumerical is not able to connect or communicate with the license server machine on TCP port 1055 or 1056. Search for ‘. Mar 18, 2014 · I uninstalled then reinstalled ANSYS and now it works. The traffic or request for a license checkout from the local computer did not reach the license server. Apr 16, 2020 · I am trying to perform explicit analysis using LS-DYNA. It consists of a simple rectangular cross-section beam subjected to a uniformly distributed load and 2 edge boundary conditions. I've just tried to re-open today but […] Hi, I'm currently experiencing the same problem win 2019 R3. com) Regards, Nanda. For clearing the %appdata% in your system. Once I started worked in folders that do not get backed up, the errors were no longer present. dll file doesn't exist there. Jun 22, 2023 · I want to transfer the forces from the solution of Ansys Maxwell to the Setup of Ansys Mechanical, for which I am using Workbench. To avoid this problem, you have to turn off User Account Control and IPv6 before installing ANSYS. db If it doesn't work then simly issue all SAVE commands with specification of full path: SAVE, Fname, Ext Read the ANSYS Help Doucmentation. For that purpose I am using the chdir command and making different attempts, namely. lock file which is in the working directory you're starting the program from? Or have you tried launching Ansys with a different working directory? The program uses the same directory where you save the WB project. 2, working on fluid flow cfx. I will post an update if I find a permanent solution for this. There are a few known issues when installing ANSYS on Windows 7. This information might be about you, your preferences or your device and is mostly used to make the site work as you expect it to. This displays a list of recently used directories. Type the directory name into the box and press Enter. Unfortunately, Ansys Workbench defines the Fluent workingdirectory as F: (which is a network accessed directory and therefore not suitable) And I can't change it in this window. perhaps in your install. -----Aniket. The Ansys client licensing log files are found in the computer that is running Ansys simulations. Ansys HFSS hangs on a blank screen in CentOS 7 (Based on Redhat) if left idle I've had a similar problem. The program uses the same directory where you save the WB project. launcher import find_ansys find_ansys() and it Aug 14, 2023 · as mentioned earlier, it appears that the shell setup runs under is unable to expand userdesktop. mechdb files from the project directory to a different location. /SYP,mkdir ,'mytest' ! Create new working directory in the current WD /CWD,'C:\default_workdir\mytest' ! Change WD to the new one save ! save . AnalysisById (0). As far as I understand, the problem is caused by background connections. License Manager option of the Ansys License Management Center to stop the license manager. I hope this post helps anyone else experiencing this problem. Open Fluent Launcher --} Show More Options --} Working Directory --} change the directory to the desktop or any existing folder in your PC Search for jobs related to Unable to get working directory ansys or hire on the world's largest freelancing marketplace with 24m+ jobs. dir directory. Ansys does not support the usage of unauthorized Ansys software. But due to AEDT in Workbench file paths get easily very long and workbench can only handle 256 characters, so be aware of that. How to access Ansys help links. The guideline on this page is to configure the Ansys license manager for shared access to the licenses on a server. For that you need to work in optiSLang and but then you can get a very robust setup, e. Dec 15, 2015 · I'm having some serious problems running Workbench Ansys 16. How do I fix this problem? Tried searching for ANSYS path with: from ansys. Sep 6, 2022 · In the job_log file, there's also a License problem. Inside dp0 you will find one or more 'AQW' folders - one for each of the Hydrodynamic Diffraction or Hydrodynamic Response systems on your Project Schematic. Feb 9, 2023 · The topic ‘unable to get working directory’ is closed to new replies. Analyses[0] solver_directory = first_analysis. workbench显示unable to get working directory怎么解决。求指导 Apr 15, 2020 · Changing working directory of SolidWorks, Creo, Abaqus, Ansys, Etc. ansys’ folder and rename it to ‘. for the GeForce card, I tried both latest gamers ready and creators ready drivers, tried reinstalling CUDA and updating the driver as a part of the installation, all without any luck. Jan 22, 2011 · Network filesystems: On Linux, it’s common to have one’s home directory on a file server for reasons of flexibility (you have access to the same files regardless of which Linux PC you login from). ) -Installing Ansys in Feb 9, 2007 · If it does just enter yes and you should be on your way. Nov 15, 2023 · Hi, I am a student trying to use HFSS to learn subjects. xml exists in your […] The topic ‘Unable to process CATIA-drawn aircraft in ANSYS’ is closed to new replies. Copy the link to the Ansys Online Help from the post on the Ansys Learning Forum. you should be able to see the FDTD file, and save it to a fsp file on you local machine. tebruw yculpz ygm mqiimm peshoh ewnfu enfsy iszeb ofucvmd ccii